PrescribeIT® Specification and Guide Version 5.0

 

Definitions for the dtprofile-identifier-prescription Profile.

1. Identifier
Definition

A technical identifier - identifies some entity uniquely and unambiguously.

Control0..*
Max Length0
2. Identifier.id
Definition

unique id for the element within a resource (for internal references).

Control0..1
Typeid
Max Length0
3. Identifier.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

Control0..*
TypeExtension
Alternate Namesextensions, user content
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Max Length0
4. Identifier.use
Definition

The purpose of this identifier.

Control0..1
BindingThe codes SHALL be taken from IdentifierUse Identifies the purpose for this identifier, if known .

Typecode
Is Modifiertrue
Requirements

Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers.

Comments

This is labeled as "Is Modifier" because applications should not mistake a temporary id for a permanent one. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary.

Max Length0
5. Identifier.type
Definition

A concept that may be defined by a formal reference to a terminology or ontology or may be provided by text.

Control1..1
BindingThe codes SHALL be taken from Identifier Type Codes; other codes may be used where these codes are not suitable A coded type for an identifier that can be used to determine which identifier to use for a specific purpose.

TypeCodeableConcept(Shared Health CodeableConcept Code)
Must Supporttrue
Requirements

Allows users to make use of identifiers when the identifier system is not known.

Comments

-

Max Length0
6. Identifier.type.id
Definition

unique id for the element within a resource (for internal references).

Control0..1
Typeid
Max Length0
7. Identifier.type.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

Control0..*
TypeExtension
Alternate Namesextensions, user content
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Max Length0
8. Identifier.type.coding
Definition

A reference to a code defined by a terminology system.

Control1..*
TypeCoding
Must Supporttrue
Requirements

Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings.

Comments

Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.

Max Length0
SlicingThis element introduces a set of slices on Identifier.type.coding. The slices are unordered and Open, and can be differentiated using the following discriminators:
  • value @ system
  • ,
  • value @ code
9. Identifier.type.coding.id
Definition

unique id for the element within a resource (for internal references).

Control0..1
Typeid
Max Length0
10. Identifier.type.coding.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

Control0..*
TypeExtension
Alternate Namesextensions, user content
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Max Length0
11. Identifier.type.coding.system
Definition

The identification of the code system that defines the meaning of the symbol in the code.

Control1..1
Typeuri
Must Supporttrue
Requirements

Need to be unambiguous about the source of the definition of the symbol.

Comments

This is the URI that represents the coding system as defined within the binding.

Max Length0
12. Identifier.type.coding.version
Definition

The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured. and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged.

NoteThis is a business versionId, not a resource version id (see discussion)
Control0..1
Typestring
Comments

Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.

Max Length0
13. Identifier.type.coding.code
Definition

A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

Control1..1
Typecode
Must Supporttrue
Requirements

Need to refer to a particular code in the system.

Comments

This is the code as defined within the binding.

Max Length0
14. Identifier.type.coding.display
Definition

A representation of the meaning of the code in the system, following the rules of the system.

Control0..1
Typestring
Must Supporttrue
Requirements

Need to be able to carry a human-readable meaning of the code for readers that do not know the system.

Max Length0
15. Identifier.type.coding.userSelected
Definition

Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays).

Control0..1
Typeboolean
Requirements

This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing.

Comments

Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.

Max Length0
16. Identifier.type.coding:placer
SliceNameplacer
Definition

A reference to a code defined by a terminology system.

Control0..*
TypeCoding
Must Supporttrue
Requirements

Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings.

Comments

Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.

Max Length0
17. Identifier.type.coding:placer.id
Definition

unique id for the element within a resource (for internal references).

Control0..1
Typeid
Max Length0
18. Identifier.type.coding:placer.extension
Definition

May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.

Control0..*
TypeExtension
Alternate Namesextensions, user content
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Max Length0
19. Identifier.type.coding:placer.system
Definition

The identification of the code system that defines the meaning of the symbol in the code.

Control1..1
Typeuri
Must Supporttrue
Requirements

Need to be unambiguous about the source of the definition of the symbol.

Comments

Fixed value: http://hl7.org/fhir/identifier-type

Max Length0
Fixed Valuehttp://hl7.org/fhir/identifier-type
20. Identifier.type.coding:placer.version
Definition

The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured. and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged.

NoteThis is a business versionId, not a resource version id (see discussion)
Control0..1
Typestring
Comments

Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.

Max Length0
21. Identifier.type.coding:placer.code
Definition

A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

Control1..1
Typecode
Must Supporttrue
Requirements

Need to refer to a particular code in the system.

Comments

Fixed value: PLAC

Max Length0
Fixed ValuePLAC
22. Identifier.type.coding:placer.display
Definition

A representation of the meaning of the code in the system, following the rules of the system.

Control0..1
Typestring
Must Supporttrue
Requirements

Need to be able to carry a human-readable meaning of the code for readers that do not know the system.

Max Length0
23. Identifier.type.coding:placer.userSelected
Definition

Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays).

Control0..1
Typeboolean
Requirements

This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing.

Comments

Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.

Max Length0
24. Identifier.type.text
Definition

A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user.

Control0..1
Typestring
Requirements

The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source.

Comments

Very often the text is the same as a displayName of one of the codings.

Max Length0
25. Identifier.system
Definition

Establishes the namespace in which set of possible id values is unique.

Control1..1
Typeuri
Must Supporttrue
Requirements

There are many sequences of identifiers. To perform matching, we need to know what sequence we're dealing with. The system identifies a particular sequence or set of unique identifiers.

Comments

Conformance Rule: This must be an OID of the URI form [Vendor root].[Application instance node].2 (e.g. urn:oid:1.2.3.4). The branch, “.2” is appended to create a unique namespace for the Prescription Identifer

Max Length0
Example
General:http://www.acme.com/identifiers/patient or urn:ietf:rfc:3986 if the Identifier.value itself is a full uri
InvariantsDefined on this element
EMR-id-branch-2: This must be an OID ending in .2 (: $this.matches('^urn\\:oid\\:(\\d+\\.)+2$'))
26. Identifier.value
Definition

The portion of the identifier typically relevant to the user and which is unique within the context of the system.

Control1..1
Typestring
Must Supporttrue
Comments

Usage Rule: The business identifier that uniquely identifies a prescription.

Max Length0
Example
General:123456
27. Identifier.period
Definition

Time period during which identifier is/was valid for use.

Control0..1
TypePeriod
Max Length0
28. Identifier.assigner
Definition

Organization that issued/manages the identifier.

Control0..1
TypeReference(Organization)
Comments

The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.

Max Length0