3.52.6 StructureDefinition: PrescribeIT Pharmacy-related Observation - Detailed Descriptions
Definitions for the profile-observation-rx Profile.
Observation | |
Definition | Measurements and simple assertions made about a patient, device or other subject. |
Control | 0..* |
Must Support | true |
Alternate Names | Vital Signs, Measurement, Results, Tests |
Comments | At present, only supported observations are height and weight. Conformance Rule: Observations of height and weight should only be sent when there is an effective date. |
Max Length | 0 |
Invariants | Defined on this element obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (: dataAbsentReason.empty() or value.empty()) obs-7: Component code SHALL not be same as observation code (: value.empty() or code!=component.code) |
Observation.id | |
Definition | The logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. |
Control | 1..1 |
Type | id |
Must Support | true |
Comments | Usage Note: This will usually be a GUID and is assigned by the sending application. Ideally it should be consistent for all messages referencing this observation measurement. |
Max Length | 0 |
Observation.meta | |
Definition | The metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content may not always be associated with version changes to the resource. |
Control | 0..1 |
Type | Meta |
Max Length | 0 |
Observation.implicitRules | |
Definition | A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. |
Control | 0..1 |
Type | uri |
Is Modifier | true |
Comments | Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element as much as possible. |
Max Length | 0 |
Observation.language | |
Definition | The base language in which the resource is written. |
Control | 0..1 |
Binding | A human language. The codes SHALL be taken from http://tools.ietf.org/html/bcp47 |
Type | code |
Comments | Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). |
Max Length | 0 |
Observation.text | |
Definition | A human-readable narrative that contains a summary of the resource, and may be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. |
Control | 0..1 This element is affected by the following invariants: dom-1 |
Type | Narrative |
Alternate Names | narrative, html, xhtml, display |
Comments | Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. |
Max Length | 0 |
Observation.contained | |
Definition | These resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. |
Control | 0..* |
Type | Resource |
Alternate Names | inline resources, anonymous resources, contained resources |
Comments | This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. |
Max Length | 0 |
Observation.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the resource. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the resource, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.identifier | |
Definition | A unique identifier for the simple observation instance. |
Note | This is a business identifier, not a resource identifier (see discussion) |
Control | 0..* |
Type | Identifier |
Requirements | Allows observations to be distinguished and referenced. |
Max Length | 0 |
Observation.status | |
Definition | The status of the result value. |
Control | 1..1 |
Binding | Codes providing the status of an observation. The codes SHALL be taken from ObservationStatus |
Type | code |
Is Modifier | true |
Must Support | true |
Requirements | Need to track the status of individual results. Some results are finalized before the whole report is finalized. |
Comments | Fixed value: final |
Max Length | 0 |
Fixed Value | final |
Observation.category | |
Definition | A concept that may be defined by a formal reference to a terminology or ontology or may be provided by text. |
Control | 1..1 |
Binding | Codes for high level observation categories . For example codes, see Observation Category Codes |
Type | CodeableConcept(Shared Health CodeableConcept Code) |
Must Support | true |
Comments | codes are from HL7 and system URL is http://hl7.org/fhir/observation-category. |
Max Length | 0 |
Observation.category.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.category.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.category.coding | |
Definition | A reference to a code defined by a terminology system. |
Control | 1..* |
Type | Coding |
Must Support | true |
Requirements | Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings. |
Comments | Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true. |
Max Length | 0 |
Observation.category.coding.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.category.coding.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.category.coding.system | |
Definition | The identification of the code system that defines the meaning of the symbol in the code. |
Control | 1..1 |
Type | uri |
Must Support | true |
Requirements | Need to be unambiguous about the source of the definition of the symbol. |
Comments | - |
Max Length | 0 |
Observation.category.coding.version | |
Definition | The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured. and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. |
Note | This is a business versionId, not a resource version id (see discussion) |
Control | 0..1 |
Type | string |
Comments | Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. |
Max Length | 0 |
Observation.category.coding.code | |
Definition | A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). |
Control | 1..1 |
Type | code |
Must Support | true |
Requirements | Need to refer to a particular code in the system. |
Max Length | 0 |
Observation.category.coding.display | |
Definition | A representation of the meaning of the code in the system, following the rules of the system. |
Control | 0..1 |
Type | string |
Requirements | Need to be able to carry a human-readable meaning of the code for readers that do not know the system. |
Max Length | 0 |
Observation.category.coding.userSelected | |
Definition | Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays). |
Control | 0..1 |
Type | boolean |
Requirements | This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. |
Comments | Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. |
Max Length | 0 |
Observation.category.coding(HL7Code) | |
Definition | A reference to a code defined by a terminology system. |
Control | 1..* |
Type | Coding |
Must Support | true |
Requirements | Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings. |
Comments | See children for fixed value |
Max Length | 0 |
Observation.category.coding.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.category.coding.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.category.coding.system | |
Definition | The identification of the code system that defines the meaning of the symbol in the code. |
Control | 1..1 |
Type | uri |
Must Support | true |
Requirements | Need to be unambiguous about the source of the definition of the symbol. |
Comments | Fixed value: http://hl7.org/fhir/observation-category |
Max Length | 0 |
Fixed Value | http://hl7.org/fhir/observation-category |
Observation.category.coding.version | |
Definition | The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured. and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. |
Note | This is a business versionId, not a resource version id (see discussion) |
Control | 0..1 |
Type | string |
Comments | Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. |
Max Length | 0 |
Observation.category.coding.code | |
Definition | A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). |
Control | 1..1 |
Type | code |
Must Support | true |
Requirements | Need to refer to a particular code in the system. |
Comments | Fixed value: vital-signs |
Max Length | 0 |
Fixed Value | vital-signs |
Observation.category.coding.display | |
Definition | A representation of the meaning of the code in the system, following the rules of the system. |
Control | 0..1 |
Type | string |
Requirements | Need to be able to carry a human-readable meaning of the code for readers that do not know the system. |
Max Length | 0 |
Observation.category.coding.userSelected | |
Definition | Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays). |
Control | 0..1 |
Type | boolean |
Requirements | This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. |
Comments | Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. |
Max Length | 0 |
Observation.category.text | |
Definition | A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. |
Control | 0..1 |
Type | string |
Requirements | The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. |
Comments | Very often the text is the same as a displayName of one of the codings. |
Max Length | 0 |
Observation.code | |
Definition | Identification of the type of measurement/observation that was made about the patient. The only two allowable types are height and weight. |
Control | 1..1 |
Binding | Pharmacy-related vital signs The codes SHALL be taken from PrescriptionObservationTypeVitalSign |
Type | CodeableConcept(Shared Health CodeableConcept Code) |
Must Support | true |
Requirements | Distinguishes what kind of information is being specified. Code is mandatory to ensure that measurements/observations are distinguishable |
Comments | Conformance Rule: Code set has a binding value set defined. |
Max Length | 0 |
Observation.code.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.code.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.code.coding | |
Definition | A reference to a code defined by a terminology system. |
Control | 1..* |
Type | Coding |
Must Support | true |
Requirements | Allows for translations and alternate encodings within a code system. Also supports communication of the same instance to systems requiring different encodings. |
Comments | Code and System will be set. For Body height code value = 8302-2 For Body weight code value = 29463-7 |
Max Length | 0 |
Observation.code.coding.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.code.coding.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.code.coding.system | |
Definition | The identification of the code system that defines the meaning of the symbol in the code. |
Control | 1..1 |
Type | uri |
Must Support | true |
Requirements | Need to be unambiguous about the source of the definition of the symbol. |
Comments | This must be https://fhir.infoway-inforoute.ca/CodeSystem/pCLOCD |
Max Length | 0 |
Observation.code.coding.version | |
Definition | The version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured. and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. |
Note | This is a business versionId, not a resource version id (see discussion) |
Control | 0..1 |
Type | string |
Comments | Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. |
Max Length | 0 |
Observation.code.coding.code | |
Definition | A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). |
Control | 1..1 |
Type | code |
Must Support | true |
Requirements | Need to refer to a particular code in the system. |
Max Length | 0 |
Observation.code.coding.display | |
Definition | A representation of the meaning of the code in the system, following the rules of the system. |
Control | 0..1 |
Type | string |
Requirements | Need to be able to carry a human-readable meaning of the code for readers that do not know the system. |
Max Length | 0 |
Observation.code.coding.userSelected | |
Definition | Indicates that this coding was chosen by a user directly - i.e. off a pick list of available items (codes or displays). |
Control | 0..1 |
Type | boolean |
Requirements | This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. |
Comments | Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. |
Max Length | 0 |
Observation.code.text | |
Definition | A human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. |
Control | 0..1 |
Type | string |
Requirements | The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. |
Comments | Very often the text is the same as a displayName of one of the codings. |
Max Length | 0 |
Observation.subject | |
Definition | A reference from one resource to another. |
Control | 1..1 |
Type | Reference(Shared Health Reference)(Shared Health Patient) |
Must Support | true |
Requirements | Observations have no value if you don't know who or what they're about. |
Comments | This must point to the patient associated with the message |
Max Length | 0 |
Observation.encounter | |
Definition | The healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made. |
Control | 0..1 |
Type | Reference(Encounter) |
Requirements | For some observations it may be important to know the link between an observation and a particular encounter. |
Max Length | 0 |
Observation.effectiveDateTime | |
Definition | When the measurement was made |
Control | 1..1 |
Type | dateTime |
Must Support | true |
Requirements | Knowing when an observation was deemed true is important to its relevance as well as determining trends. |
Comments | At least a date should be present unless this observation is a historical report. |
Max Length | 0 |
Observation.issued | |
Definition | The date and time this observation was made available to providers, typically after the results have been reviewed and verified. |
Control | 0..1 |
Type | instant |
Comments | Updated when the result is updated. |
Max Length | 0 |
Observation.performer | |
Definition | Who was responsible for asserting the observed value as "true". |
Control | 0..* |
Type | Reference(Practitioner | Organization | Patient | RelatedPerson) |
Requirements | May give a degree of confidence in the observation and also indicates where follow-up questions should be directed. |
Max Length | 0 |
Observation.valueQuantity | |
Definition | A measured amount (or an amount that can potentially be measured). Note that measured amounts include amounts that are not precisely quantified, including amounts involving arbitrary units and floating currencies. |
Control | 1..1 |
Type | Quantity(Shared Health Quantity) |
Must Support | true |
Requirements | An observation exists to have a value, though it may not if it is in error, or it represents a group of observations. |
Comments | Conformance Rule: This MUST be expressed in kilograms (weight), and centimeters (height). Value, System and Code will be set. For Body height; value - set to height measurement in centimeters system = http://unitsofmeasure.org code = cm For Body weight: value - set to weight measurement in kilograms system = http://unitsofmeasure.org code = kg |
Max Length | 0 |
Invariants | Defined on this element qty-3: If a code for the unit is present, the system SHALL also be present (: code.empty() or system.exists()) |
Observation.dataAbsentReason | |
Definition | Provides a reason why the expected value in the element Observation.value[x] is missing. |
Control | 0..1 This element is affected by the following invariants: obs-6 |
Binding | Codes specifying why the result (Observation.value[x]) is missing. The codes SHALL be taken from Observation Value Absent Reason; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Requirements | For many results it is necessary to handle exceptional values in measurements. |
Comments | Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values. |
Max Length | 0 |
Observation.interpretation | |
Definition | The assessment made based on the result of the observation. Intended as a simple compact code often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Otherwise known as abnormal flag. |
Control | 0..1 |
Binding | Codes identifying interpretations of observations. The codes SHALL be taken from Observation Interpretation Codes; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Requirements | For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. |
Alternate Names | Abnormal Flag |
Max Length | 0 |
Observation.comment | |
Definition | May include statements about significant, unexpected or unreliable values, or information about the source of the value where this may be relevant to the interpretation of the result. |
Control | 0..1 |
Type | string |
Requirements | Need to be able to provide free text additional information. |
Max Length | 0 |
Observation.bodySite | |
Definition | Indicates the site on the subject's body where the observation was made (i.e. the target site). |
Control | 0..1 |
Binding | Codes describing anatomical locations. May include laterality. For example codes, see SNOMED CT Body Structures |
Type | CodeableConcept |
Requirements | Knowing where the observation is made is important for tracking if multiple sites are possible. |
Comments | Only used if not implicit in code found in Observation.code. If the use case requires BodySite to be handled as a separate resource instead of an inline coded element (e.g. to identify and track separately) then use the standard extension body-site-instance. |
Max Length | 0 |
Observation.method | |
Definition | Indicates the mechanism used to perform the observation. |
Control | 0..1 |
Binding | Methods for simple observations. For example codes, see Observation Methods |
Type | CodeableConcept |
Requirements | In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results. |
Comments | Only used if not implicit in code for Observation.code. |
Max Length | 0 |
Observation.specimen | |
Definition | The specimen that was used when this observation was made. |
Control | 0..1 |
Type | Reference(Specimen) |
Comments | Observations are not made on specimens themselves; they are made on a subject, but usually by the means of a specimen. Note that although specimens are often involved, they are not always tracked and reported explicitly. Also note that observation resources may be used in contexts that track the specimen explicitly (e.g. Diagnostic Report). |
Max Length | 0 |
Observation.device | |
Definition | The device used to generate the observation data. |
Control | 0..1 |
Type | Reference(Device | DeviceMetric) |
Comments | An extension should be used if further typing of the device is needed. Devices used to support obtaining an observation can be represented using either extension or through the Observation.related element. |
Max Length | 0 |
Observation.referenceRange | |
Definition | Guidance on how to interpret the value by comparison to a normal or recommended range. |
Control | 0..* |
Type | BackboneElement |
Requirements | Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. |
Comments | Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g. specific to the patient's age, gender, weight and other factors), but this may not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties. |
Max Length | 0 |
Invariants | Defined on this element obs-3: Must have at least a low or a high or text (: low.exists() or high.exists() or text.exists()) |
Observation.referenceRange.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.referenceRange.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.referenceRange.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.referenceRange.low | |
Definition | The value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3). |
Control | 0..1 This element is affected by the following invariants: obs-3 |
Type | Quantity(SimpleQuantity) |
Max Length | 0 |
Observation.referenceRange.high | |
Definition | The value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3). |
Control | 0..1 This element is affected by the following invariants: obs-3 |
Type | Quantity(SimpleQuantity) |
Max Length | 0 |
Observation.referenceRange.meaning | |
Definition | Code for the meaning of the reference range. |
Control | 0..1 |
Binding | Code for the meaning of a reference range. For example codes, see Observation Reference Range Meaning Codes |
Type | CodeableConcept |
Requirements | Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, or perhaps what state this reference range applies to (i.e. age, hormonal cycles, etc.). |
Comments | This SHOULD be populated if there is more than one range. |
Max Length | 0 |
Observation.referenceRange.age | |
Definition | The age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so. |
Control | 0..1 |
Type | Range |
Requirements | Some analytes vary greatly over age. |
Max Length | 0 |
Observation.referenceRange.text | |
Definition | Text based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of 'normals'. |
Control | 0..1 |
Type | string |
Max Length | 0 |
Observation.related | |
Definition | A reference to another resource (usually another Observation but could also be a QuestionnaireAnswer) whose relationship is defined by the relationship type code. |
Control | 0..* |
Type | BackboneElement |
Requirements | Normally, an observation will have either a value or a set of related observations. A few observations (e.g. Apgar score) may have both a value and a set of related observations or sometimes QuestionnaireResponse from which the measure is derived. |
Comments | For a discussion on the ways Observations can assembled in groups together see Notes below. |
Max Length | 0 |
Observation.related.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.related.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.related.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.related.type | |
Definition | A code specifying the kind of relationship that exists with the target resource. |
Control | 0..1 |
Binding | Codes specifying how two observations are related. The codes SHALL be taken from ObservationRelationshipType |
Type | code |
Requirements | A relationship type SHOULD be provided. |
Comments | "derived-from" is only logical choice when referencing QuestionnaireAnswer resource. |
Max Length | 0 |
Observation.related.target | |
Definition | A reference to the observation or QuestionnaireResponse resource that is related to this observation. |
Control | 1..1 |
Type | Reference(Observation | QuestionnaireResponse) |
Max Length | 0 |
Observation.component | |
Definition | Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations. |
Control | 0..* |
Type | BackboneElement |
Requirements | Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation. |
Comments | For a discussion on the ways Observations can assembled in groups together see Notes below. |
Max Length | 0 |
Observation.component.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Observation.component.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.component.modifierExtension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element, and that modifies the understanding of the element that contains it. Usually modifier elements provide negation or qualification. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. |
Control | 0..* |
Type | Extension |
Is Modifier | true |
Alternate Names | extensions, user content, modifiers |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Observation.component.code | |
Definition | Describes what was observed. Sometimes this is called the observation "code". |
Control | 1..1 This element is affected by the following invariants: obs-7 |
Binding | Codes identifying names of simple observations. For example codes, see LOINC Codes |
Type | CodeableConcept |
Requirements | Knowing what kind of observation is being made is essential to understanding the observation. |
Max Length | 0 |
Observation.component.value[x] | |
Definition | The information determined as a result of making the observation, if the information has a simple value. |
Control | 0..1 |
Type | Choice of: Quantity, CodeableConcept, string, Range, Ratio, SampledData, Attachment, time, dateTime, Period |
[x] Note | See Choice of Data Types for further information about how to use [x] |
Requirements | An observation exists to have a value, though it may not if it is in error, or it represents a group of observations. |
Comments | Normally, an observation will have either a value or a set of related observations. A few observations (e.g. Apgar score) may have both a value and related observations (for an Apgar score, the observations from which the measure is derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For boolean values use valueCodeableConcept and select codes from <http://hl7.org/fhir/ValueSet/v2-0136> (These "yes/no" concepts can be mapped to the display name "true/false" or other mutually exclusive terms that may be needed"). The element, Observation.value[x], has a variable name depending on the type as follows: valueQuantity, valueCodeableConcept, valueRatio, valueChoice, valuePeriod, valueSampleData, or valueString (The name format is "'value' + the type name" with a capital on the first letter of the type). |
Max Length | 0 |
Observation.component.dataAbsentReason | |
Definition | Provides a reason why the expected value in the element Observation.value[x] is missing. |
Control | 0..1 This element is affected by the following invariants: obs-6 |
Binding | Codes specifying why the result (Observation.value[x]) is missing. The codes SHALL be taken from Observation Value Absent Reason; other codes may be used where these codes are not suitable |
Type | CodeableConcept |
Requirements | For many results it is necessary to handle exceptional values in measurements. |
Comments | "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values. |
Max Length | 0 |
Observation.component.referenceRange | |
Definition | Guidance on how to interpret the value by comparison to a normal or recommended range. |
Control | 0..* |
Type | See Observation.referenceRange |
Requirements | Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. |
Comments | Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g. specific to the patient's age, gender, weight and other factors), but this may not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties. |
Max Length | 0 |