3.33.6 StructureDefinition: PrescribeIT Drug Quantity - Detailed Descriptions
Definitions for the dtprofile-quantity-drug Profile.
Quantity | |
Definition | A measured or counted amount of a medication expressed as a value and human-readable string with optional coded units expressed in a local coding system |
Control | 0..* |
Must Support | true |
Comments | Usage Note: Quantity is used throughout the messages. It may be a drug form (e.g. TAB) an administrable drug (e.g. PUFF) form or a unit of measure (e.g. mg). |
Max Length | 0 |
Invariants | Defined on this element qty-3: If a code for the unit is present, the system SHALL also be present (: code.empty() or system.exists()) sqty-1: The comparator is not used on a SimpleQuantity (: comparator.empty()) |
Quantity.id | |
Definition | unique id for the element within a resource (for internal references). |
Control | 0..1 |
Type | id |
Max Length | 0 |
Quantity.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. In order to make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Control | 0..* |
Type | Extension |
Alternate Names | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Max Length | 0 |
Quantity.value | |
Definition | The value of the measured amount. The value includes an implicit precision in the presentation of the value. |
Control | 1..1 |
Type | decimal |
Must Support | true |
Requirements | Precision is handled implicitly in almost all cases of measurement. |
Comments | The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books). |
Max Length | 0 |
Quantity.comparator | |
Definition | Not allowed to be used in this context |
Control | 0..0 |
Binding | How the Quantity should be understood and represented. The codes SHALL be taken from QuantityComparator |
Type | code |
Is Modifier | true |
Requirements | Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology. |
Comments | This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value. |
Max Length | 0 |
Meaning if Missing | If there is no comparator, then there is no modification of the value |
Quantity.unit | |
Definition | A human-readable form of the unit. |
Control | 1..1 |
Type | string |
Must Support | true |
Requirements | There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms. |
Comments | Usage Note: This must be used to convey the english display that is associated with the code. (Note: Rationale for change: to accommodate fax template) |
Max Length | 0 |
Quantity.system | |
Definition | The identification of the system that provides the coded form of the unit. |
Control | 0..1 This element is affected by the following invariants: qty-3 |
Type | uri |
Must Support | true |
Requirements | Need to know the system that defines the coded form of the unit. |
Max Length | 0 |
Quantity.code | |
Definition | A computer processable form of the unit in some unit representation system. |
Control | 0..1 |
Binding | The codes SHALL be taken from PrescribedQuantityUnit; other codes may be used where these codes are not suitable |
Type | code |
Must Support | true |
Requirements | Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest. |
Comments | Conformance Rule: A Code must be supplied if one is available from the PrescribedQuantityUnit subset. If the user picks a prescribed quantity unit that does not have a code in the PrescribedQuantityUnit subset, only then can unit be supplied without a code. If a receiving system receives a code that it doesn't recognize, the system must just display the unit. |
Max Length | 0 |